Data logging and processing equipment

The pulse from triggering switch is employed to trigger the digital recording system and the signals from transducers are sent to Data Acquisition System (DAQ) through signal conditioning cards. The system components are:

Data Acquisition System
System controller : Pentium-IV PC with standard/latest peripherals including modems
Operating System : Window XP
Application Software : NI LabVIEW 8.0 , MATLAB 6.5 on Windows Platform
Data Acquisition Card : NI PCI – 6220 M, 2 DAQ cards are installed on the PC. The first DAQ card is for receiving signals from the trigger and the second one is for controlling signal conditioning module.
Signal Conditioning System
Signal Conditioning System : NI SCXI-1000 Chassis (4 Slot)
Signal Conditioning Card : NI SCXI-1520: 4 cards of 8 channels each (total 24 channels used) universal strain/bridge module with mounting terminal block (4 units of NI SCXI 1314) & chassis
 
   
Data Acquisition Card Signal Conditioning Card

Triggering Switch : A switch is used for automatic starting of the system for data acquisition when the train approaches the instrumented rail.
Power Supply : The system will be able to operate on AC 230 V nominal, 50 Hz Single phase supply.
Other Accessories : NI SCB –Junction Box, NI SHC68-68 Cable, NI SXCI-1349 Connector, NI CB 68LP

©2008, IIT Kanpur, All Rights Reserved