Expt 9: Measurement of Droplet Size for an Air-Assist Atomizer

Spray visualization



    Development stages of a spray
    To play video click here

    2D view of a well developed spray
    To play video click here


SMD variation with GLR



  • SMD decreased with GLR for a given axial distance (ZR) downstream of orifice.

  • SMD at a given GLR decreased with ZR.

  • At higher GLR, increased momentum of air caused more turbulence, due to which SMD decreased drastically by collision and breakup of larger drops.

  • Secondary atomization results in decreased droplet size at ZR = 150 mm as compared to ZR = 100 mm.



Droplet size distribution at ZR = 150 mm





  • Increase in the volume fraction occupied by particles of smaller SMD at higher GLR.

  • Size distribution is increasingly skewed towards lower SMD as GLR increases.

  • Earlier secondary atomization at higher GLR due to increased turbulence.



Effect of GLR on size distribution





  • At a given GLR, increased secondary atomization at ZR = 150 mm decreased the volume fraction of the largest droplet size.

  • Higher GLR operation is able to reduce the volume fraction of largest droplet size more effectively.